- General Assay & Diagnostic Apparatus[6]
- EL Products[6]
- Emergency & Clinics Apparatus[6]
- Ultrasonic[6]
- Ward Nursing Equipments[6]
- Clinical Analytical Instruments[6]
- Medical Software[6]
- Healthcare Supplement[6]
- Medical Consumables[6]
- Surgical Instruments[6]
- Physical Therapy Equipments[6]
- Body Fluid-Processing & Circulation Devices[1]
- Pumps[1]
- Dental Equipments[6]
- Other Analysis Instruments[1]
- Veterinary Instrument[6]
- Testing Equipment[1]
- Sterilization Equipments[1]
- Contact Person : Ms. Wang Jenny
- Company Name : Rising Medical Equipment Co., Ltd.
- Tel : 86-10-51290013
- Fax : 86-10-59812390
- Address : Beijing,Beijing,Suite 506, Longguan Zhiye Plaza, Huilongguan, Changping District, Beijing, 102208, China
- Country/Region : China
- Zip : 102208
Related Product Searches:Infusion Pump,High Quality,top infusion pump, iv infusion pump,IP-50
Functions:
Automatic infusionKVO (Keep Vein Open)It will give audible and visible alarm and then switch to KVO mode after finish infusing the preset volumeAudible and visible alarmThe pump has OCCLUSION, AIR IN LINE, DOOR OPEN, FINISH, LOW BATT, INTERRUPTION, ABNORMAL and DELAY OPERATION alarm functionsAC/DCWhen the pump stops, purge function is ended to purge air out of line. Double click bolus button to purge. Contrarily, it infuses fastFlow rate settingSet the flow rate between: Drop/min, ml/h and time infusion volumeSelf-check after startupWhen power on, the pump executes a self-check. LCD display and all lamps will be lighten if it works normally. The corresponding lamp will be off if any part doesn’t workAccumulated volume display and clearMemory functionMemory can keep the parameters which you set up last time over 8 yearsFlow rate calibrationIn order to make infusion accurate, calibrate the infusion set according to actual situationSpecifications:
Flow Rate | 1ml/h~1300ml/hMore than 1000ml/h, 1ml/h stepLess than 1000ml/h, 0.1ml/h step |
Standard IV SET | ±5% |
Preset infusion volume | 1ml~9999mlMore than 1000ml, 1ml stepLess than 1000ml, 0.1ml step |
Occlusion sensitivity | Optional choose from higher to lower |
KVO rate | 1~5ml/h (adjustable) |
Power supply | 110~220+10%, 50~60Hz+1Hz |
Power consumption | Less than 20VA |
Battery Life | More than 3 hours continuously at 30ml/h with fully charged battery |
Work Condition | Circumstance Temperature: 10 ~40°C infusion precision will decrease when temperature ≤18°C Relative Humidity: 30~93% Atmospheric Pressure: 86~106KPa |
Applicable scope | Fit for mainline, small volume infusion, quick infusion |
|
|
|
|